The radiometers measure UV light intensity for a specific wavelength (254nm, 312nm or 365nm). They are designed for an accurate and direct measurement of the UV radiation. All our radiometers use a silicon photo-electric for a direct measurement of the UV intensity and thus do not convert UV into visible light.
VLX-3W
The VLX-3W is a highly accurate and user friendly radiometer. The radiometer is controlled by a microprocessor to measure the UV radiation dosage according to two parameters: time (mn or sec) or energy (J:cm²). The VLX-3W is connectable to three interchangeable sensors.
UV-3W
UV-3W are single wavelength radiometer. They measure the UV intensity for either short wave (254nm), middle wave (312nm) or long wave (365nm).

UV-3W radiometer
• 254 312 365nm (three models)
• Electronic case
• LCD display
• Analog output
• Zero drift
• Off/On/Hold switch
UV sensor (fixed)
• Silicon photo-electric cell for a direct measurement of the UV radiation. No need for conversion into visible light.
• Interference filter to select the appropriate UV band and to eliminate all other unwanted radiation.
• Non-sensitive to infra-red.
• No electronic components in the sensor to avoid any possible temperature disparity
• Quartz disc protection on cell filter
• Carbon shielded cable (1 metre)
VLX-3W radiometer with microprocessor
• Designed for operating at 254nm, 312nm and 365nm
• Independent sensor (supplied separately) for each wavelength
• Analog output on the rear panel for each wavelength
• 4 X 16 LCD display
• 4 ‘Alkaline’ batteries R6/1.5V
|
VLX-3W |
UV-3W |
| 3 interchangeable sensors, Hold button and storage of min and max intensity |
Radiometer with Hold button and recorder output |
| Measruement Range |
Intensity: 0-350 mW/cm^2; Energy: 0-99999 Joules/cm^2; Time: 0 sec-99 hrs |
Intensity: 0-200 mW/cm^2 |
| Integrated bandwidth with spectral curves of low pressure lamps |
SX-254: monochromatic; SX-312: 280-320nm; SX-365: 355-375nm |
3 different model, one for ea wavelength |
| Resolution |
Auto-ranging; 1st range: 0-3.5; 2nd range: 3.51-35; 3rd range: 35.1-350 mW/cm^2 |
Auto-ranging; 1st range: 0-1.9999; 2nd range: 2.00-19.99; 3rd range 20.0-200 mW/cm^2 |
| Display Type |
LCD display, 4 Lines 16 Characters |
LCD display, 3 1/2 digit |
| Analog output Sensore |
0-3.5V for 0-350mW/cm^2; silicon phot-electric cell interference filter diffuser in quartz |
0-2.0V for 0-200mW/cm^2; silicon photo-electric cell interference filter diffuser in quartz |
| Sensor Accuracy |
+5% |
+5% |
| Cat. No. |
Descriptaion |
| UV-3W |
Radiometer with hold button and recorder output |
| VLX-3W |
Radiometer with 3 interchangeable sensors(separate), hold button and storage or min & max intensity |
| SX-254 |
Sensor 254nm |
| SX-312 |
Sensor 312nm |
| SX-365 |
Sensor 365nm |