One and dual block Genius Dry Bath Incubators use interchangeable heating block modules for a variety of applications, including restriction digests, denaturing DNA, BUN, melting agar, coagulation studies, hybridization and Hot Start thermo-cycled reaction, in addition to the function of water bath. All models incorporate a PID controller for easy temperature selection, rapid heat up and excellent stability. Temperature may be set in 0.1℃ increments from 5℃ above ambient to 150℃. An optional temperature probe is available for placing directly in samples. A timer equipped may be set from 0 to 999 mins for user's convenience. In addition to the optional Data Logging software package, another optional Function Control software package controls dry bath incubator through a computer.


-
Microprocessor control with digital performance
-
Wide temperature control range
-
Great temperature controlled performance
-
Timer function
-
User Calibration
-
Used as water bath incubator
-
Data log software package available
-
Function control software package available
-
Controller: digital microprocessor controller
-
Display: one digital display
-
Temperature control range: 5ËšC above ambient to 150ËšC
-
Temperature increase: 0.1ËšC
-
Temperature calibration: Yes
-
Temperature uniformity @37˚C: ± 0.2˚C
-
Temperature accuracy @37˚C: ± 0.2˚C
-
Timer: 0-999 mins
-
Safety device: leakage proof for heating chamber
-
Operating temperature: ambient to 40ËšC
-
Special feature: used as water bath incubator
-
Heating chamber material: 304 stainless steel
-
Block material: aluminum
-
Block type: standard and customized types are available
-
Data Log: RS 232
-
Rated voltage: 110V or 220V
-
Unit Dimension: W200 x L290 x H80 mm
-
Weight: 2.6 kg for MD-01N; 2.8 kg for MD-02N

| Cat. No. |
Description |
| MD-01N-110/220 |
Genius Dry Bath Incubator (One Block Unit); without block |
| MD-02N-110/220 |
Genius Dry Bath Incubator (Dual Block Unit); without block |
| Accessories |
Description |
| MD-MP01-S |
Block for Microplate ; Titerplate Plain Block for Single Block Unit Only |
| MD-MP02-S |
Block for 96 wells deep Microplate or PCR plateFor Single Block Unit Only |
| MD-MP01-D |
Block for Microplate ; TiterplateFor Dual Block Unit Only |
| MD-MP02-D |
Block for 96 wells deep Microplate or PCR plateFor Dual Block Unit Only |
| MD-B0.5/1.5 |
Double side block : one side for 1.5 or 2.0 ml tube, 20 wells ;Opposite side for 0.5 ml tube, 30 wells |
| MD-B0.5+1.5 |
Combination block : for 0.5 ml tube, 12 wells and for 1.5 or 2.0 ml tube, 12 wells (on the same side) |
| MD-B0.2 |
Block for 0.2 ml tube, 64 wells or for 0.2 ml PCR strip tubes for 8 wells x 8 |
| MD-B0.5 |
Block for 0.5 ml tube, 20 wells |
| MD-B1.5 |
Block for 1.5 ml tube, 20 wells |
| MD-B10 |
Block well size 10 mm, 20 wells |
| MD-B13 |
Block well size 13 mm, 20 wells |
| MD-B17 |
Block for 15 ml centrifuge tube, 12 wells |
| MD-B20 |
Block well size 20 mm, 12 wells |
| MD-B25 |
Block well size 25 mm, 6 wells |
| MD-B29 |
Block for 50 ml centrifuge tube, 4 wells |
| MD-DLSW |
Single Licensed Software Package for data logging |
| MD-PCSW |
Single Licensed Software Package for control function |
| MD-DLSW-R |
Single Licensed Software Package for data logging, including a RS 232 Cable |
| MD-PCSW-R |
Single Licensed Software Package for control function, including a RS 232 Cable |